Start a project

Services

01KNX smart home02Energy management03Energy for businesses04Building automation05Electrical planning06KNX reconstruction & service07KNX programming

Company

Projects Guides (German) About SmartEnergy Contact Start a project

Energy management for businesses in Hamburg & Pinneberg districtAre you paying for 15 expensive minutes a year?

For businesses with interval metering, the highest load peak of the year often drives a large share of grid costs. We show when and why it happens – and coordinate chargers, machines, pumps, PV and storage so it doesn't happen in the first place.

Sound familiar?

Typical situations.

  • New chargers – and the grid operator talks about upgrading the connection.
  • In the morning everything starts at once: machines, compressor, heating, charging.
  • The PV system feeds in at midday while expensive power is drawn in the evening.
  • Heat pump, cooling or pumps run uncoordinated.
  • Nobody knows exactly which load causes the peak.
  • A roof renovation is due – and with it Hamburg's solar requirement.

Interactive

A working day in your business – and where the costly peak comes from.

Lower your peak loads – we check your savings potential.

Request a load profile check →

Your benefits

What we do.

01

Evaluate existing load data and electricity bills

02

Temporary metering of main loads where data is missing

03

Identify peak drivers and prioritise measures

04

Dynamic load management for chargers, machines and pumps

05

Bring PV, battery, heat pump and wallboxes into one concept

06

Monitoring and alerts – so it stays that way

Industries

Where we start.

01

Car dealership & workshop

Chargers for customer, demo and fleet vehicles meet lifts, compressors and heating.

  • Prioritise charging instead of upgrading the connection
  • Solar power for the fleet
  • Transparency per area
02

Trades & production

Ovens, extraction, compressed air and machines create short, costly peaks – often avoidable by sequencing.

  • Start sequences instead of simultaneity
  • Check compressed air & standby
  • Link peaks to specific processes
03

Tree nursery & horticulture

Irrigation pumps, cold stores and large roofs: lots of potential when pumps and PV work together.

  • Stagger pump starts
  • Cooling with solar power
  • Irrigation based on soil moisture

Also: owner-run hotels, fitness & wellness businesses, business parks and office buildings.

Starting point

Energy & peak-load check

Measure first, then decide. A structured starting point for businesses that want to understand where their load peaks come from.

Your result: a clear assessment with prioritised areas for action – without blanket savings promises or hasty investment recommendations.

Request the check →
  1. Short initial call about your business, tariff and goals
  2. Review of electricity bill and existing load data
  3. On-site visit, temporary metering if needed
  4. Evaluation: what causes the peak – and what helps most?

Remote monitoring

Informed before it gets critical.

Load profile, PV generation, charge points and system status – in view even when you are off site. Defined events notify the people responsible; when a peak looms, the system staggers flexible loads automatically.

See

  • Load profile and current peak
  • PV generation and battery
  • Charge points and system status

Control

  • Charging power and priorities
  • Lighting and heating by occupancy
  • Zones, doors and schedules

Notified

  • Limit reached or exceeded
  • Fault or component not reachable
  • Door or window open after closing time

Notification channels, recipients and automatic actions are defined with you – including roles and permissions. We only access your system remotely with your approval.

Smart company

What your business can handle automatically.

Trigger → Reaction → Notification

Hall & office

  • Presence in a zoneLight and heat only where people are working
  • Enough daylightHall lighting dims smoothly
  • Closing timeLights off, doors closed, heating down, alarm armedAlert if anything is left open

Energy & fleet

  • Peak loomingCharge points and flexible loads are staggeredWarning to those responsible
  • Fleet returnsCharging plan by departure time and priorityCharging progress
  • PV surplusFleet, battery or heat firstLive energy flow

Security & operations

  • Unauthorised accessLighting and security routine startsPush to defined recipients
  • Cooling gets too warmBackup kicks in, if installedAlert before the limit
  • System reports a faultSafe state or fallback modeAlarm message
  • Service interval reachedMaintenance need is flaggedService notice

Examples – which routines make sense for your business is decided after an on-site assessment. Cameras and access systems must also respect employees' rights. Savings depend on operations, usage and tariff.

Process

How it works.

01

Initial call

15 minutes: your business, tariff, chargers, PV and what bothers you.

02

Data & measurement

Load profile from the grid portal, bills, our own measurement if needed.

03

Analysis

Peak drivers, load-shifting potential, PV and battery effect.

04

Implementation

Load management, control and monitoring – with specialist partners where needed.

Honest boundaries

What we don't do – and what we do with partners.

Not with us

  • Blanket savings promises without reliable data
  • Recommend a battery just because there's a PV system
  • Funding promises or funding advice with guaranteed success
  • Change your operations without agreeing them with you

With specialist partners

  • Grid connection upgrades and coordination with the grid operator
  • PV, battery, charging and HVAC work outside our scope
  • Medium voltage, refrigeration safety, machine controls
  • Funding and tax advice

FAQ

Good to know.

What are interval metering (RLM) and demand charges?

RLM (German interval metering) records not just consumption but demand in 15-minute intervals. Depending on contract and tariff, the highest relevant peak in a billing period can set the demand charge – so a brief overlap of large loads can matter financially. Your contract and bill are what count.

Do I need a battery for this?

Not necessarily. Often it's enough to stagger loads or limit charging power dynamically. A battery can make sense – whether it pays off only the load profile can show.

Can we add chargers without upgrading the grid connection?

Dynamic load management often fits more charging power into the existing connection. Whether that's enough depends on connection capacity, load profile and charging needs – which the check examines.

Is there funding?

Funding programmes change often and come with conditions. We point out possible options but don't replace funding advice and make no promises.

What data do you need – and what happens to it?

Helpful are electricity bills, existing load-profile files and information on operating hours and large loads. We agree in advance which data is needed, how it is transferred and who has access – and use it only for the agreed purpose under agreed deletion and privacy rules.

How long do you need to measure?

It depends on your operations, seasonality and the data available. Existing load profiles often give a first overview; if typical or seasonal conditions are missing, we add a measurement phase. We set the duration after the initial check.

Start a project

Let's connect your building.

Enquire Call